Retrofit S7-300/400 to S7-1500
Siemens has discontinued the S7-300 including ET 200M. Since 1 October 2025 it has only been available as a spare part, and only for a limited time. We migrate your S7-300 and S7-400 plants to S7-1500 with TIA Portal: completely in one shutdown or step by step, before a failure determines the timing.
Fixed-price retrofit
Upload a photo of the control cabinet and your documents, tell us how your S7 or S5 program can reach us, and receive a fixed-price quotation. Free and without obligation.
Why plan now
The S7-300 and the ET 200M distributed I/O have no longer been regularly available since 1 October 2025. Siemens still supplies them as spare parts, usually for around ten years. Module prices rise considerably in this phase, delivery times become unpredictable, and with STEP 7 classic on old programming devices the software becomes a bottleneck too.
The S7-400 is still available but is at the end of its life cycle. If you run an S7-400 today, plan the migration together with your next major modification.
What we migrate
- S7-300 and S7-400 with STEP 7 classic to S7-1500 with TIA Portal
- S7-400H to S7-1500R/H
- ET 200M to ET 200SP or ET 200MP, step by step if required
- PROFIBUS to PROFINET where it makes sense
- WinCC flexible and panels such as OP77, TP177 or MP277 to WinCC Unified
- S7-200 to S7-1200 and Simatic S5 to S7-1500
- Alternatively to Beckhoff TwinCAT 3 if that is your plant standard

Topics in detail
Every plant is different. These are the most common starting points.
S7-400 and S7-400H
Move large and high-availability controllers to S7-1500 or S7-1500R/H.
Learn moreET 200M
Replace I/O step by step or keep using it on the new CPU for now.
Learn morePROFIBUS to PROFINET
Modernise the network without replacing every device at once.
Learn moreWinCC flexible and panels
Replace OP77, TP177, MP277 and similar with current operator panels.
Learn moreProgram missing or protected
Retrieve the S7 program from the CPU and make it readable again.
Learn moreSimatic S5
Move S5 plants without spare part supply safely to S7-1500.
Learn moreAll at once or step by step
Not every plant can stand still long enough for a complete conversion. That is why we also offer the migration in stages.
Complete migration
CPU, I/O, network and operator panels are replaced in one planned shutdown. Afterwards the plant runs entirely on current hardware.
Partial migration
First only the CPU is replaced by an S7-1500. The ET 200M stays in operation via PROFIBUS or a PROFINET interface module and is replaced later in short shutdowns.
Prepared and tested
The new program is built and tested in advance in our office, with simulation if required. On site, the work is limited to the conversion and commissioning.
What a partial migration can look like
- Stage 1: CPUS7-1500 instead of S7-300/400. The ET 200M stays connected, the program already runs in TIA Portal.
- Stage 2: I/OET 200M station by station to ET 200SP or ET 200MP, each in a short shutdown, wiring reused via adapters where possible.
- Stage 3: Network and HMIPROFIBUS to PROFINET and old panels to WinCC Unified whenever it fits your planning.
More than converting
The migration tool in TIA Portal does a lot, but not everything. Typical issues are system functions that no longer exist on the S7-1500, absolute addressing, indirect access via pointer and ANY, organisation blocks that behave differently and third-party blocks. We check the result block by block, clean up legacy issues and test before the conversion.
If you wish, we rebuild the program in a structured way, in SCL, LAD or FBD, with a clean alarm system and comments. The process follows our retrofit process. You receive the new program unencrypted.
No project available any more?
Often only the program in the CPU exists, without symbols and comments, or nobody is sure whether the last project version is the current one. We retrieve the program from the controller, make it readable again and document it. We know this from years of work with discontinued Klöckner Moeller controllers. More on program recovery.

Frequently asked questions
Do I have to migrate right away?
Not necessarily, but you should plan now. The supply of spare parts for discontinued products is limited in time and is becoming more expensive. A planned retrofit is much cheaper than an emergency.
Can the existing wiring remain?
Often yes, for example with front connector adapters or pre-assembled cabling systems. What is possible in your plant is clarified during the survey.
Can I keep running the ET 200M on the new CPU?
Yes, via PROFIBUS or a PROFINET interface module. This way the CPU can be replaced first and the I/O later in short shutdowns.
How long will the plant be down?
That depends on the scope. Because the program is finished and tested in advance, a weekend or a single shift is often enough for a CPU migration.
The project can no longer be found. Is it still possible?
Yes. We read the program out of the CPU and reconstruct symbols and comments far enough for a clean migration.
Is Beckhoff also possible instead of S7-1500?
Yes, if Beckhoff is your standard. The program is then transferred to TwinCAT 3.
Which controller runs your plant?
Send us the CPU type, year of manufacture and a photo of the control cabinet. You will get an honest assessment of whether spare part stocking, a partial migration or a complete retrofit makes sense.